| Model: SPA800 Weight: 2600g Dimension/CTN. /Pcs: 66x36.5x36.5cm / 9pcs Features: 1)Input protections: Polarity reverse / Over and under voltage / Low battery Alarm and shut down 2)Output protections: Short circuit / Overload / Over temperature 3)charge power/public power and inverter/protection, intelligent LED indication 4)Input and output fully isolation 5)Low power consumption(standby) 6)inverter and public power intelligently switch, load can properly work without switch 7)LVD meet EN60950 and E8 mark 8)EMC meet EN61000-6-1-3, EN55022 Auto re-start function: When the inverter shuts off once it being in protection, it is not necessary to press the switch (on/off), just moving the high loads, the inverter can restart automatically. So there is no need to place the spare fuse. This product is built with UPS auto conversion: When the main power is shut off, the unit can be changed automatically to supply the power by inverter, but after the main power resume, the inverter stop work automatically, and get into the state chargin for battery Specifications: Inverter Part 1) Max. Continuous output power: 800W 2) Surge capability peak output power: 1600W 3) DC input static current (no load): ¡1.0AMP 4) AC output wave form: Modified Sine wave 5) Normal input voltage range: 11-15V / 21~30V 6) High voltage cut off level: >15V / 30V 7) Low voltage alarm: 10.6V+ -0.3V(DC12V) / 20.5V+ -0.5V(DC24V) 8) Low voltage cut off level: 9.5V+ -0.5V(DC12V) / 19.5V+ -0.5V(DC24V) 9) Output AC voltage: AC 115V+ -5% RMS / AC 230V + -5% RMS 10) Output frequency level: 60HZ+ -1Hz / 50HZ 11) Overload power range: 800W, 5-30% 12) Hi-pot test: PRI/sec, 1500V/AC 5mA/60s 13) Temperature protection: <65c 14) Full load max. Optimum efficiency: ¡Ý90% 15) AC output short circuit protection: System shut down (no damage) 16) Fan run: Working with load 17) Fault warning: Alarm beep 18) LED indicator: A) Normal: Green B) Fault: Red green 19) Fuse (spade type): 40Ax 3pcs 20) Dimensions (L x W x H): 275x 176 x 77mm 21) Environmental condition: A) Operating temperature: -5~45c B) Operating relative humidity: 10-90% RH C) Storage temperature: -10~50c D) Storage relative humidity: 10-95% RH Charger Part: Charger Current: 10A (constant current) Input voltage range: AC115V / AC230V + -10% Input charger power Fuse: 10A LED indicator: A) green: Public power /charge B) Red: Fully charge Charge ON/OFF switch (inverter, power inverter, dc to ac power inverter, solar power inverter, power inverter factory) |
Do you want to show products of your own company? Join FREE now!